3M N95 Reg. ParticulateResp.Mask 20 b

Medical Supplies

3M N95 Reg. ParticulateResp.Mask 20 b Medical Supplies

Regular price $40.29 $40.29
Sale

3M N95 Reg. ParticulateResp.Mask 20 b

Medical Supplies

Availability : In stock

Share
Earn Regular price 41 Vita Reward Points

Regular price $40.29 $40.29
Sale

FREE SHIPPING

Health Care Particulate Respirator and Surgical Mask 

Fluid Resistant 

Latex Free 

Warning: 
This respirator helps protect against certain particulate contaminants but does not eliminate exposure to the risk of contracting any disease or infection. Misuse may result in sickness or death 

IMPORTANT 
Before use, the wearer must read and understand these User Instructions inside. Misuse may result in sickness or death 

DESCRIPTION 
The 3M™ 1860 Health Care Particulate Respirator and Surgical Mask is designed to help provide respiratory protection for the wearer. This product has a filter efficiency level of 95% or greater against particulate aerosols free of oil*. It is fluid resistant, disposable and may be worn in surgery. It can fit a wide range of face sizes. This product contains no components made from natural rubber latex

INTENDED USE: This product meets CDC guidelines for Mycobacterium tuberculosis exposure control. As a respirator, it is intended to reduce wearer exposure to certain airborne particles in a size range of 0.1 to >10.0 microns, including those generated by electrocautery, laser surgery, and other powered medical instruments. As a surgical mask, it is designed to be fluid resistant to splash and spatter of blood and other infectious materials; when worn properly and in combination with protective eyewear, it complies with the OSHA Bloodborne Pathogens Standard. It also provides >99% BFE** against wearer generated micro-organisms 

CONTRAINDICATIONS: Not for industrial use. Not for use with beards or other facial hair that prevents direct contact between the face and the sealing surface of the respirator. This respirator can help reduce inhalation exposures to certain airborne biological particles (e.g. mold, avian influenza viruses, Bacillus anthrasis, Mycobacterium tuberculosis, ect.) but cannot eliminate the risk of contracting infection, illness, or disease. OSHA and other government agencies have not established safe exposure limits for these contaminants. This respirator is designed for occupational/professional use by adults who are properly trained in their use and limitations. This respirator was not designed to be used by children 

USE INSTRUCTIONS: 

1. Before use for respiratory protection, a written respiratory protection program must be implemented meeting all requirements of OSHA 29 CFR 1910.139 and/or 1910.134 such as medical evaluation, training and fit testing. In Canada, CSA standard Z94.4 requirements must be met. The 3M saccharin (sweet solution) or FT-30 (bitter solution) qualitative fit test apparatus is recommended for this respirator. When used only as a surgical mask, fit testing is not required

2. Respirator may be used until damaged, breathing becomes difficult, or contaminated with blood or body fluids. Otherwise, it may be stored and reused according to the facility's infection control policy. Discard after every use when used for surgical procedures 

3. Inspect respirator before each use to ensure that it is in good operating condition. Examine all the respirator parts for signs of damage including the two headbands, staples, noseclip, and nosefoam. The respirator should be disposed of immediately upon observation of damaged or missing parts 

4. Filtering facepieces are to be inspected prior to each use to assure there are no holes in the breathing zone other than the punctures around staples and no damage has occurred. Enlarged holes resulting from ripped or torn filter material around staple punctures are considered damage. Immediately replace respirator if damaged. Staple perforations do not affect NIOSH approval 

Meets CDC guidelines for Mycobacterium tuberculosis exposure control 

NIOSH Approved: N95 
At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil 

Not intended for Individual resale 

* Tested against a 0.3 micron particle (count median diameter) per 42 CFR 84. 
** Bacterial Filtration Efficiency (BFE) determined by the modified Greene and Vesley test method

Delivery Formats:
Pieces

Active Ingredients:
Masks

Description

Health Care Particulate Respirator and Surgical Mask 

Fluid Resistant 

Latex Free 

Warning: 
This respirator helps protect against certain particulate contaminants but does not eliminate exposure to the risk of contracting any disease or infection. Misuse may result in sickness or death 

IMPORTANT 
Before use, the wearer must read and understand these User Instructions inside. Misuse may result in sickness or death 

DESCRIPTION 
The 3M™ 1860 Health Care Particulate Respirator and Surgical Mask is designed to help provide respiratory protection for the wearer. This product has a filter efficiency level of 95% or greater against particulate aerosols free of oil*. It is fluid resistant, disposable and may be worn in surgery. It can fit a wide range of face sizes. This product contains no components made from natural rubber latex

INTENDED USE: This product meets CDC guidelines for Mycobacterium tuberculosis exposure control. As a respirator, it is intended to reduce wearer exposure to certain airborne particles in a size range of 0.1 to >10.0 microns, including those generated by electrocautery, laser surgery, and other powered medical instruments. As a surgical mask, it is designed to be fluid resistant to splash and spatter of blood and other infectious materials; when worn properly and in combination with protective eyewear, it complies with the OSHA Bloodborne Pathogens Standard. It also provides >99% BFE** against wearer generated micro-organisms 

CONTRAINDICATIONS: Not for industrial use. Not for use with beards or other facial hair that prevents direct contact between the face and the sealing surface of the respirator. This respirator can help reduce inhalation exposures to certain airborne biological particles (e.g. mold, avian influenza viruses, Bacillus anthrasis, Mycobacterium tuberculosis, ect.) but cannot eliminate the risk of contracting infection, illness, or disease. OSHA and other government agencies have not established safe exposure limits for these contaminants. This respirator is designed for occupational/professional use by adults who are properly trained in their use and limitations. This respirator was not designed to be used by children 

USE INSTRUCTIONS: 

1. Before use for respiratory protection, a written respiratory protection program must be implemented meeting all requirements of OSHA 29 CFR 1910.139 and/or 1910.134 such as medical evaluation, training and fit testing. In Canada, CSA standard Z94.4 requirements must be met. The 3M saccharin (sweet solution) or FT-30 (bitter solution) qualitative fit test apparatus is recommended for this respirator. When used only as a surgical mask, fit testing is not required

2. Respirator may be used until damaged, breathing becomes difficult, or contaminated with blood or body fluids. Otherwise, it may be stored and reused according to the facility's infection control policy. Discard after every use when used for surgical procedures 

3. Inspect respirator before each use to ensure that it is in good operating condition. Examine all the respirator parts for signs of damage including the two headbands, staples, noseclip, and nosefoam. The respirator should be disposed of immediately upon observation of damaged or missing parts 

4. Filtering facepieces are to be inspected prior to each use to assure there are no holes in the breathing zone other than the punctures around staples and no damage has occurred. Enlarged holes resulting from ripped or torn filter material around staple punctures are considered damage. Immediately replace respirator if damaged. Staple perforations do not affect NIOSH approval 

Meets CDC guidelines for Mycobacterium tuberculosis exposure control 

NIOSH Approved: N95 
At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil 

Not intended for Individual resale 

* Tested against a 0.3 micron particle (count median diameter) per 42 CFR 84. 
** Bacterial Filtration Efficiency (BFE) determined by the modified Greene and Vesley test method

Specifications

Delivery Formats:
Pieces

Additional Information

Active Ingredients:
Masks

Reviews

\